Retour

Taro

Static Balancing Machine
  • Without rotation – simple and precise balancing
  • Rotor weight from 200….3.600 kg
  • Determination of unbalance and rotor weight
  • No drive and no safety device required
  • Short measuring times
  • Efficient measuring unit CAB 945; operation by Touch Screen

Special characteristics

  • Permanent calibration due to new  measuring principle, i.e. no later adjustments of measuring mimic
  • Low operating- and maintenance cost
  • Low maintenance
  • The machine requires no foundation, simply set it up, fasten three bolts, connect power, and the machine is ready to balance
  • Little space required
  • Various special functions, such as automation, indexing function or integration of lifting table
Conception

Range of application

Measuring of static unbalance of disc-shaped rotors, as e.g. grinding wheels, propellers, brake discs, railway wheels, pump impellers.
Calculation of the unbalance correction; applicable for adding or removing masses.
Applicable for pure unbalance measurement, for tasks with unbalance correction in production, intake control and for final balancing. Moreover the rotor weight is determined automatically.
Données techniques
Technical data at a glance     
Measuring unit    CAB 759 
Color touch screen    •  
Combined measuring / correction station    •  
Manual loading    •  
Automatic cycle    •  
Automatic load/unload door    •  
Clamp tool actuation unit (push-to-unlock)    •  
Horizontal and vertical drilling    •  
Spindle drive system    servo 
Drill feed    servo 
Drill speed    FC 
Changeover     manual 
     
Rotor     
Weight, max. 2)  [kg]  30 
Diameter, max.  [mm]  500 
Brake disc height, max.  [mm]  150 
Machine     
Width A 4)  [mm]  1200 
Depth B 4)  [mm]  2700 
Height C 4)  [mm]  1800 
Balancing speed  [min -1]  600-1000 
Measuring uncertainty 1)  [gmm] 
Air pressure  [kPa]  600 
Supply power  [V-Hz]  3x400-50/60 
Power consumption  [kVA]  10 
Color  RAL7035 (light grey) and  RAL7024 (graphite grey) 
     
Options     
Interface for auto load/unload     
Vacuum unit     
     
1) Acc. To DIN 1319, 95% probability, work-piece dependent     
2) Rotor plus adapter